Key ............................................. SCR-00211B00 JAN Type ........................................ SCR-211B Nomenclature .................................... Frequency Meter Set Reference ....................................... TM 11-300 Components ...................................... BC-221B Frequency Meter, 6 ea BA-2 22.5 V Battery, 4 ea BA-23 1.5 V Battery. Weight .......................................... 38 Lbs Frequency Range ................................. 0.125-20 MHz Power In ........................................ 6 & 135 VDC from Batteries Description: The SCR-211B Frequency meter is used to measure frequency in the range 0.125 to 20 MHz. It is battery powered. Part Of ......................................... SCR-211B Source .......................................... TM 11-300, Jul 44 Manufacturer .................................... Allen D. Cardwell Mfg. Corporation Tube Complement ................................. 2 ea 6SJ7 & 6K8.


If you are uncertain about the JAN designator for a particular system or component please use the "Index" or "System" button to list all the systems and components in the database. You can click on the designator for the closest system or component You can click on the designator for the closest system or component.